FXT | Baltimore Aircoil Company

By: Baltimore Aircoil  11-11-2011
Keywords: Natural Resources, Evaporative Cooling, Cooling Towers

Low Installed Cost

•All single cell FXT Cooling Towers ship completely assembled, minimising installation time and costs:

•No motors to mount

•No pulleys to align

•No belts to install

•No make-up system to assemble

Low Energy Consumption

• Evaporative Cooling Equipment - Minimizes the energy consumption of the entire system because it provides lower condensing water temperatures. Owners save money while conserving natural resources and reducing environmental impact.

• The FXT provides the heat rejection required at the lowest possible energy input via:

•High efficiency, low horsepower axial fans

•High efficiency BACross® Fill, which provides maximum air/water contact time at low air pressure drops

•VFD duty motors are standard while Variable Frequency Drives are optional.

•Premium Efficient Motors (optional)

Easy Maintenance

•Easy access – The interior of the unit is accessible through a circular access door for adjusting the float valve, cleaning the strainer, or flushing the basin.

•Motor location – The fan motor is located on the exterior of the unit for easy maintenance and belt adjustment. On most models, a single threaded bolt and nut assembly further simplifies belt adjustment.

•Easy lubrication – Fittings for extended lubrication lines are provided as standard on the exterior of the unit for bearing lubrication. 

Long Service Life

• Materials of Construction - Various materials are available to meet the corrosion resistance, unit operating life, and budgetary requirements of any project.

Keywords: Cooling Equipment, Cooling Towers, Duty Motors, Energy Consumption, Evaporative Cooling, Evaporative Cooling Equipment, Materials Of Construction, Natural Resources,

Other products and services from Baltimore Aircoil

11-11-2011

Products | Baltimore Aircoil Company

Closed circuit cooling towers operate in a manner similar to open cooling towers, except that the heat load to be rejected is transferred from the process fluid to the ambient air through a heat exchange coil. Evaporative condensers provide heat rejection for many types of systems, and the specific application will largely determine which BAC Evaporative Condenser is best suited for a project.


11-11-2011

Open Circuit Cooling Towers | Baltimore Aircoil Company

The axial fans of induced draft equipment are mounted in the top deck of the unit, minimizing the impact of fan noise on nearby neighbors and providing maximum protection from fan icing with units operating in sub-freezing conditions.


11-11-2011

VXT | Baltimore Aircoil Company

Materials of Construction - Various materials are available to meet the corrosion resistance, unit operating life, and budgetary requirements of any project. Indoor Installations: Centrifugal fans can overcome the static pressure imposed by external ductwork, allowing the VXT to be installed indoors. Support - All models mount directly on two parallel I-beams and ship complete with motors and drives factory-installed and aligned.


11-11-2011

Closed Circuit Cooling Towers | Baltimore Aircoil Company

This creates two separate fluid circuits: an external circuit, in which spray water circulates over the coil and mixes with the outside air, and an internal circuit, in which the process fluid circulates inside the coil. Closed circuit cooling towers operate in a manner similar to open cooling towers, except that the heat load to be rejected is transferred from the process fluid to the ambient air through a heat exchange coil.


11-11-2011

FXV | Baltimore Aircoil Company

The cleanable header tube bundle provides removable cover plates on the inlet and outlet header boxes to permit access to each serpentine tube circuit for solvent or air-pressure cleaning. The low sound levels generated by FXV Closed Circuit Cooling Towers make them suitable for installation in most environments. Tubes are all prime surface steel tubing formed into a serpentine shape and welded into an assembly.


11-11-2011

VFL | Baltimore Aircoil Company

Low Profile Models– Motors and drives of low profile units are adjacent to the casing section to yield models suitable for use in height sensitive installations. Attenuation - For extremely sound sensitive applications, factory designed tested/rated sound attenuation is available for both the air intake and discharge.